Paper 1
Patient NameMohamed Abdelmomen
Age81
Clinical evaluation
Consultation date01/30/2025
Previous assessment for TAVIno
History and risk factors
Prior CABGno
Prior aortic valve procedureno
Prior other valve procedureno
Number of previous cardiac surgerynone
Prior arrhythmiano
Permanent peacemakerno
Other history
Previous CVA or TIAno
Extracardiac arteriopathyno
Hypertensionyes
Diabetes melitusyes
Renal insufficiency requiring dialysisyes
Renal insufficiency requiring renal transplantno
Chronic lung diseaseno
Malignancy (prior or current)no
Paper 2
Clinical evaluation continued
Syncopeno
CCSno
Clinical data
Hemoglobin (g/dl)13.4
Creatinine (mg/dl)1.2
Pre-operative special investigations
ECG
Rhythmregular
PR Interval (ms)120
QRS Duration (ms)85
ECHO (TTE or TOE)
Mean gradient across aortic valve (mm Hg)45
Aortic valve area (cm2)0.9
Ejection fraction (%)55
Associated valvular lesions
Aortic insufficiencynone
Mitral insufficiencymild
Mitral stenosisnone
Tricuspid insufficiencynone
Tricuspid stenosisnone
Pulmonary insufficiencynone
Pulmonary stenosisnone
Paper 3
TAVI evaluation
Risk profile
Contra-indication to surgeryno
Reason for contra-indication to surgery
Frailtyno
Porcelain aortano
Patent LIMA graftno
Hostile thoraxno
Further investigations
Lung function testsno
Angiogramno
PCI or revascularization indicatedno
CT coronary angiogramno
Pre TAVI CT Assessment
Aortic Annulus
Perimeter (mm)79
Perimeter derived (mm)25
LVOT
Perimeter (mm)85
Perimeter derived (mm)26
Sinus of Valsalva
Left29
Right27
Non28
Measurements
Aortic Annulus
LVOT
STJ angle
LCA Height10
RCA Height13
Aortic Valve Calcificationsevere
Aortic Root Angulation34
Paper 4
TAVI procedure
TOE used intra-operativelyno
Valve in valve procedureno
Procedural successno
Procedural complications (VARC < 72 hours)
Intra-procedural mortalityno
Consequent mortality < 72 hr post-procedureno
Myocardial infarctionno
Stroke or TIAno
New PMLno
Bleeding complicationsno
Vascular complicationno
Valve dysfunctionno
Other thrombotic or embolic complicationsno
Cardiopulmonary bypass requiredno
Other procedural complicationsno
Conversion to open heart surgeryno
Device information
Number of valves implantednone
Valve 1
Type implantedMedtronic
Medtronic data
Model implantedEvolut R
Size implanted34
Valve resultnot-detectable
Boston data
Hospital stay
Paper 5
Follow up information
General follow up
Stroke / TIA since TAVIno
PPM since TAVIno
Hospital admissionno
Follow up 30 days
Stroke / TIA since TAVIno
PPM since TAVIno
Scroll to Top