Paper 1
Patient NameSabah Desouky
Age67
Clinical evaluation
Consultation date11/22/2024
Previous assessment for TAVIno
History and risk factors
Prior CABGno
Prior aortic valve procedureno
Prior other valve procedureno
Number of previous cardiac surgerynone
Prior arrhythmiano
Permanent peacemakerno
Other history
Previous CVA or TIAno
Extracardiac arteriopathyno
Hypertensionyes
Diabetes melitusyes
Renal insufficiency requiring dialysisno
Renal insufficiency requiring renal transplantno
Chronic lung diseaseno
Malignancy (prior or current)no
Paper 2
Clinical evaluation continued
Syncopeno
CCSno
NYHAII
Clinical data
Height (cm)166
Weight (kg)77
Hemoglobin (g/dl)13.2
Creatinine (mg/dl)1.1
Pre-operative special investigations
ECG
Rhythmregular
PR Interval (ms)130
QRS Duration (ms)95
ECHO (TTE or TOE)
Mean gradient across aortic valve (mm Hg)44
Aortic valve area (cm2)0.7
Associated valvular lesions
Aortic insufficiencynone
Mitral insufficiencymild
Mitral stenosisnone
Tricuspid insufficiencynone
Tricuspid stenosisnone
Pulmonary insufficiencynone
Pulmonary stenosisnone
Paper 3
TAVI evaluation
Risk profile
Predicted operative risklow
STS score (%)2.3
Euroscore II (%)1.2
Contra-indication to surgeryno
Reason for contra-indication to surgery
Frailtyno
Porcelain aortano
Patent LIMA graftno
Hostile thoraxno
Further investigations
Lung function testsno
Angiogramno
PCI or revascularization indicatedno
CT coronary angiogramno
Pre TAVI CT Assessment
Aortic Annulus
Perimeter (mm)75.2
Perimeter derived (mm)23.6
AREA (mm2)423
Area derived (mm)23
LVOT
Perimeter (mm)75.5
Perimeter derived (mm)24
AREA (mm2)400
Area derived (mm)22
Sinus of Valsalva
Measurements
Aortic Annulus
LVOT
STJ angle
Aortic Valve CalcificationModerate
Paper 4
TAVI procedure
TOE used intra-operativelyno
Valve in valve procedureno
Procedural successno
Procedural complications (VARC < 72 hours)
Intra-procedural mortalityno
Consequent mortality < 72 hr post-procedureno
Myocardial infarctionno
Stroke or TIAno
New PMLno
Bleeding complicationsno
Vascular complicationno
Valve dysfunctionno
Other thrombotic or embolic complicationsno
Cardiopulmonary bypass requiredno
Other procedural complicationsno
Conversion to open heart surgeryno
Device information
Number of valves implantednone
Valve 1
Type implantedMedtronic
Medtronic data
Model implantedEvolut R
Size implanted29
Boston data
Hospital stay
Paper 5
Follow up information
General follow up
Stroke / TIA since TAVIno
PPM since TAVIno
Hospital admissionno
Follow up 30 days
Stroke / TIA since TAVIno
PPM since TAVIno
Scroll to Top