Paper 1
Patient NameFawziyah Hussein Ismail
Age77
Clinical evaluation
Consultation date09/09/2024
Previous assessment for TAVIno
History and risk factors
Prior CABGno
Prior aortic valve procedureno
Prior other valve procedureno
Number of previous cardiac surgerynone
Prior arrhythmiano
Permanent peacemakerno
Other history
Previous CVA or TIAno
Extracardiac arteriopathyno
Hypertensionyes
Diabetes melitusyes
Renal insufficiency requiring dialysisno
Renal insufficiency requiring renal transplantno
Chronic lung diseaseno
Malignancy (prior or current)no
Paper 2
Clinical evaluation continued
Syncopeno
CCSyes
NYHAI
Clinical data
Height (cm)165
Weight (kg)80
Body mass index (BMI)31.7
Hemoglobin (g/dl)12.5
Creatinine (mg/dl)1.1
Creatinine clearance72
Pre-operative special investigations
ECG
RhythmRegular
PR Interval (ms)130
QRS Duration (ms)85
ECHO (TTE or TOE)
Mean gradient across aortic valve (mm Hg)40
Aortic valve area (cm2)0.8
Ejection fraction (%)74
Associated valvular lesions
Aortic insufficiencynone
Mitral insufficiencymild
Mitral stenosisnone
Tricuspid insufficiencynone
Tricuspid stenosisnone
Pulmonary insufficiencynone
Pulmonary stenosisnone
Paper 3
TAVI evaluation
Risk profile
Predicted operative riskLow
STS score (%)1.36
Euroscore II (%)0.9
Contra-indication to surgeryno
Reason for contra-indication to surgery
Frailtyno
Porcelain aortano
Patent LIMA graftno
Hostile thoraxno
Further investigations
Lung function testsno
Angiogramyes
Number of diseased vessels2
PCI or revascularization indicatedyes
CT coronary angiogramyes
Pre TAVI CT Assessment
Aortic Annulus
Perimeter (mm)71.3
Perimeter derived (mm)22.7
AREA (mm2)403.8
Area derived (mm)22.1
LVOT
Perimeter (mm)69.3
Perimeter derived (mm)22.8
AREA (mm2)356.4
Area derived (mm)21.5
Sinus of Valsalva
Left30.4
Right27.3
Non27
MAX Ascending Aorta Angle31.2
STJ Angle25.3
Measurements
Aortic Annulus
Min Aortic Annulus Diameter (mm)20.3
Max Aortic Annulus Diameter (mm)25.7
Average Aortic Annulus Diameter23.4
LVOT
Min LVOT diameter16.4
Max LVOT diameter26.1
Average Aortic Annulus Diameter21.7
STJ angle
Min25.3
Max26.4
Average25.7
LCA Height11.3
RCA Height16.4
Aortic Valve CalcificationModerate
Aortic Root Angulation39
Paper 4
TAVI procedure
Procedure date09/10/2024
Type of anesthesialocal
TOE used intra-operativelyno
Valve in valve procedureno
Procedural successyes
Procedural complications (VARC < 72 hours)
Intra-procedural mortalityno
Consequent mortality < 72 hr post-procedureno
Myocardial infarctionno
Stroke or TIAno
New PMLno
Bleeding complicationsno
Vascular complicationno
Valve dysfunctionno
Other thrombotic or embolic complicationsno
Cardiopulmonary bypass requiredno
Other procedural complicationsno
Conversion to open heart surgeryno
Device information
Number of valves implanted1
Valve 1
Type implantedBoston
Medtronic data
Boston data
Model implantedACURATE neo2
Size implantedM
Valve resultnot-detectable
Hospital stay
Days in ICU1
Days in ward1
Paper 5
Follow up information
General follow up
Stroke / TIA since TAVIno
PPM since TAVIno
Hospital admissionno
Follow up 30 days
Stroke / TIA since TAVIno
PPM since TAVIno
Scroll to Top